Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
1.
Chinese Medical Equipment Journal ; (6): 97-101, 2018.
Article in Chinese | WPRIM | ID: wpr-700028

ABSTRACT

The advantages and disadvantages of different treatment methods of traditional tibial fracture were summarized. The research progress on the treatment of tibial fracture with internal fixation plates as external fixators was introduced from two aspects of biomechanics and clinical application. It was proved that internal fixation plates as external fixators could reduce the structural stability, but this technique was still controversial to meet the mechanical requirements of fracture healing on biomechanics.Internal fixation plates as external fixators,it had the advantages of minimal invasion,high healing rate, less complications and favorable activities. It's pointed out clinical trials on its feasibility and availability as well as simulating body mechanics environment should be carried out to provide basis for relevant biomechanics researches.

2.
Chinese Medical Equipment Journal ; (6): 34-36, 2018.
Article in Chinese | WPRIM | ID: wpr-699960

ABSTRACT

Objective To design a new type of external fixator for bone fracture and verify its rationality and feasibility. Methods The frame and screw of stainless steel achieved fracture fixation in vitro with a threaded locking structure.At the same time the increasing thickness of body frame, the inclined nail holes and the raised bottoms were designed to greatly enhance the strength and overall stability of body frame.FEM (finite element method),measuring the relative displacement and stress distribution after axial load,was used to verify the rationality of the design.An animal experiment with sheep was used to verify the feasibility of fracture treatment. Results Simulated result of FEM indicated that the biggest relative displacement between the separated bones was 0.04 mm,which was much less than the minimum value 1 mm required for fracture healing.The maximum stresses applied on the frame of the fixator,fixator screw,and bone were 35,26,and 6 MPa, respectively, which was much less than the allowable stress. In the animal experiment, fracture site was fixed firmly after operation and was well cured 3 months later.Conclusion The design of this new device is feasible and it can be used as a new method of fracture treatment.

3.
Chinese Medical Equipment Journal ; (6): 106-109,145, 2017.
Article in Chinese | WPRIM | ID: wpr-699915

ABSTRACT

The main species and research status were introduced for the haemostatic dressing of the prehospital first aid in foreign countries and China.The advantages and disadvantages,problems and futural development were analyzed for kinds of haemostatic dressing.It's pointed out that the haemostatic dressing tended to be multi-functional and complicated in the future.Dressing and haemostatic system had to be designed based on traumatic conditions in case multi function could not be realized.

4.
Chinese Medical Journal ; (24): 2337-2342, 2013.
Article in English | WPRIM | ID: wpr-322201

ABSTRACT

<p><b>BACKGROUND</b>Double plate osteosynthesis is the standard treatment for intra-articular fractures of the distal humerus. However, there is still controversy concerning dual plate positions in terms of providing optimal stability. The purpose of this retrospective study was to compare the clinical outcomes in patients with type C intra-articular distal humeral fractures using perpendicular and parallel plating methods.</p><p><b>METHODS</b>Between March 2008 and June 2011, a total of 45 patients with type C distal humerus fractures were treated using two different dual plating methods. Of them, 24 patients were treated by perpendicular plating (group I) and 21 patients were treated by parallel plating (group II). The surgical time, blood loss, and union time were compared between the two groups. The flexion-extension arc, the total range of flexion and extension at the end of follow-up were compared between the two groups. The Mayo Elbow Performance Score (MEPS) was used to determine the elbow functional results.</p><p><b>RESULTS</b>All patients were followed up. The mean duration of follow-up was 16 months (range 12 - 25 months) in group I and 15.5 months in group II (range 12 - 25 months). There were no significant differences in the surgical time, blood loss, and the bone union time between the two groups. In group I, the mean elbow flexion-extension arc was 101° and the mean MEPS was 85 points. The rate of excellent and good results was 87.5%. In group II, the mean flexion-extension arc was 100° and the mean MEPS was 86.1 points. The rate of excellent and good results was 90.5%. There were no significant differences in the MEPS, flexion-extension arc, and the total range of flexion and extension between the two groups.</p><p><b>CONCLUSIONS</b>Perpendicular and parallel plate configurations with the appropriate surgical techniques can provide anatomical reconstruction and stable fixation of type C intra-articular distal humeral fractures and allow early mobilization of the elbow after an operation. The occurrence of post-operative elbow stiffness can be reduced and good outcomes can be obtained.</p>


Subject(s)
Adult , Aged , Female , Humans , Male , Middle Aged , Bone Plates , Fracture Fixation, Internal , Methods , Humeral Fractures , General Surgery , Retrospective Studies
5.
Chinese Journal of Orthopaedics ; (12): 1261-1265, 2011.
Article in Chinese | WPRIM | ID: wpr-671637

ABSTRACT

ObjectiveTo investigate the application of intraoperative Computed Tomograph (CT) using in surgery for complex acetabular fractures.MethodsFrom June 2008 to December 2010,14 patients (9 males,5 females; with the mean age of 45.1 years; range,28-62 years) with complex acetabular fractures were operated using intraoperative CT.Preoperative radiotherapy and CT scan were adopted to evaluate the fractures.Three dimensional reconstruction based on CT scan was used to mimic surgery.The surgery approach and the type of internal fixators were noted.Intraoperative C-arm and CT scan were used to evaluate the fractures reduction respectively.Decision of additional reduction was made by surgeons according to above mentioned methods respectively and the results were noted.Comparing to preoperative design,the change of surgery plan were noted.Overall time,frequency and radiation dose of intraoperative CT scan were also noted.ResultsAll patients in this study received average 2.7 times of intraoperative CT scan.Mean time of CT scan was 40.4 min and the overall dose of radiation was 47.2 mGy.Decision of additional reduction was made in 3 cases according to C-arm radiography and 4 cases according to CT scan (above mentioned 3 cases were included).The change of surgery plan was made in one case.In postoperative radiography evaluation according to Matta's score system,anatomical reduction were achieved in 8 cases,imperfect reduction in 3 cases and poor reduction in 3 cases.ConclusionIntraoperative CT scan increases the radiation time and dose of patients dramatically.When used to evaluate fracture reduction intraoperatively,it can't take the advantage of traditional C-arm radiography.When delicate preoperative plan is made with radiography and three dimensional reconstruction based on CT data,the efficiency of intraoperative CT scan for complex acetabular fractures are to be discussed.

6.
Chinese Journal of Surgery ; (12): 647-650, 2010.
Article in Chinese | WPRIM | ID: wpr-360769

ABSTRACT

<p><b>OBJECTIVE</b>To report the clinical outcome of the treatment of compound ankle fractures by vacuum sealing drainage and spanning external fixator.</p><p><b>METHODS</b>From April 2005 to April 2009, 19 cases of Gustilo type III compound ankle fractures were treated, with type IIIA in 10 cases, Type IIIB in 7 and Type IIIC in 2. All cases underwent emergency debridement, and had the fractures fixed with spanning external fixator following indirect reduction, the wound closed with vacuum sealing drainage and repaired through direct suture, split-thickness skin graft or flap transposition.</p><p><b>RESULTS</b>In this series, following VSD of 5.0 to 18.0 d (mean 10.3 d), 2 cases had their wounds closed by direct suture, 12 by skin graft and 3 by flap transposition. The other 2 cases had repeated wound debridement and multiple use of VSD, and had their wounds repaired by flap transposition. All the 19 cases were followed up for 8 to 36 months with an average of 26 months. All the fractures united 3.0 to 10.0 (mean 3.8) months. At the final follow-up functional evaluation of the affected ankle joints was performed only to find excellent in 9 cases, good in 5, fair in 4 and poor in 1.</p><p><b>CONCLUSION</b>Gustilo type III compound ankle fracture can effectively be treated with VSD and spanning external fixator.</p>


Subject(s)
Adult , Aged , Humans , Middle Aged , Young Adult , Ankle Injuries , General Surgery , External Fixators , Follow-Up Studies , Fracture Fixation , Methods , Fractures, Open , General Surgery , Negative-Pressure Wound Therapy , Treatment Outcome
7.
China Journal of Orthopaedics and Traumatology ; (12): 261-263, 2008.
Article in Chinese | WPRIM | ID: wpr-307038

ABSTRACT

<p><b>OBJECTIVE</b>To evaluate the effects of tibial shaft fractures treatment with plate-screw or intramedullary interlocking nail.</p><p><b>METHODS</b>Thirty-five fractures were treated with intramedullary interlocking nail. Tape A, B and C were 11, 18 and 6 cases respectively according to AO classification. Forty-five fractures were treated with plate-screw system. Type A,B and C were 10,22 and 13 cases respectively. The mean time between injury and operation was 3 days and 3.5 days respectively. The patients were evaluated with operation time,range of motion,time of bone union,and complications after a mean followup of 13 months(range 8 to 26 months).</p><p><b>RESULTS</b>The mean operation time and the mean range of motion of the ankle and knee were found similar in both groups. The average dorsiflexion angle of ankle was 13 Degrees (0 degrees to 20 degrees) in locked intramedullary nailing group and 11 degrees (0 degree to 20 degrees) in plate group. The average plantar flextion angle of ankle was 41 degrees (30 degrees to 50 degrees) in locked intramedullary nailing group and 47 degrees (30 degrees to 50 degrees) in plate-screw group. The mean time of bone union was 3.3 months with intramedullary nailing and 3.5 months with plate-screw fixation. Length discrepancy occurred in only two patients (2 and 2.5 cm) with intramedullary interlocking nail. One patient treated by intramedullary interlocking nail for a type III open fracture occured osteomyelitis. Plain radiographs showed rotation in two patients with intramedullary interlocking nail and angulation in 3 patients with plate-screw fixation, which were distal-third tibial fractures.</p><p><b>CONCLUSION</b>Plate-screw osteosynthesis could attain satisfactory results in uncomminuted tibia shaft fractures, and locked intramedullary nailing is more appropriate in comminuted fractures.</p>


Subject(s)
Adolescent , Adult , Female , Humans , Male , Middle Aged , Bone Nails , Bone Plates , Bone Screws , Fracture Fixation, Intramedullary , Methods , Tibial Fractures , General Surgery
8.
Chinese Journal of Surgery ; (12): 870-874, 2005.
Article in Chinese | WPRIM | ID: wpr-306193

ABSTRACT

<p><b>OBJECTIVE</b>To set up a new process to access the preparation of decellularized artery grafts. And to evaluate the feasibility of decellularized artery allografts was evaluated.</p><p><b>METHODS</b>This study compared the effects of four extraction chemicals [1% t-octyl-phenoxypolyethoxyethanol (Triton X-100), 1% tri (n-butyl) phosphate (TnBP), and 1% sodium dodecyl sulfate (SDS) and trypsin (0.125, 0.25%) on thoracic artery vascular for 24 h (except trypsin for 2 h). At the base of it, a four-step process, including hypotonic, hypertonic solutions and combining with 1% Triton X-100 and 1% SDS detergents, were performed in rabbit thoracic artery vascular. Histological examination, tensile tests and expanding-burst tests were done on the samples. The decellularized carotid artery allografts were transplanted in other rabbits.</p><p><b>RESULTS</b>Treatment with 1% SDS or 1% Triton X-100 for 24 h could remove most cells with retention of near normal structure. A four-step process could remove all cells with the extracellular matrix well conserved. The pulling mechanical properties and burst pressure of decellularized carotid artery were similar to the control. The decellularized carotid artery allografts (diameter of 2 mm) were patent at explanting up to 2 months.</p><p><b>CONCLUSIONS</b>The acellular artery vascular graft matrix is well prepared with four-step process including detergents, such as TritonX-100, SDS without compromising the graft structure or mechanical properties significantly. The carotid artery allografts (diameter of 2 mm) decellularized by the process are patent at explanting up to 2 months.</p>


Subject(s)
Animals , Female , Male , Rabbits , Aorta, Thoracic , Cell Biology , Bioprosthesis , Blood Vessel Prosthesis , Blood Vessel Prosthesis Implantation , Carotid Arteries , Cell Biology , Transplantation , Feasibility Studies , Protease Inhibitors , Pharmacology , Sodium Dodecyl Sulfate , Pharmacology , Tissue Engineering , Methods
SELECTION OF CITATIONS
SEARCH DETAIL